  • Product Name: Ultrasonic Hardness Tester TIME®5620 Nondestructive UCI method

TIME®5620 ultrasonic portable hardness tester adopts Ultrasonic Contact Impedence (UCI) testing method. Compared to traditional hardness testing methods, it leaves the least indentation, which can be considered nondestructive. It can test almost any kind of workpieces, small and thin parts as well as large parts. 

Features of TIME5620 Ultrasonic Hardness Tester

● Perfect accuracy, within±3% HV, ±1.5HR,±3%HB

● Least destructive microscopic indentation—only high-power microscope can observe the indentation

● Quick measurement——result in 2 seconds

● Large LCD display——directly showing measurement result, loading force, counts, maximum, minimal, average values and deviation.

● 2 year warranty on tester (Probe not included)

● Memory of 1000 groups data

● Simple calibration——save 20 groups calibration data to improve calibration efficiency.

 
Standard Delivery  
Main unit 1
2Kgf manual probe HP-2k 1
Probe silicone cap 1
Probe cable 1
USB cable 1
Accessories box 1
TIME certificate 1
Warranty card 1
Instrument manual 1

 

Technical Specification of TIME5620 Ultrasonic Hardness Tester

Product name

Ultrasonic hardness tester

Model

TIME-5620

Code#

#882-121

Loading force

2Kgf(optional: 1Kgf, 5Kgf, 10Kgf)

Measuring range

HB: 85-650;HV 80-1599; HRC 20-70;HRB:

41-100; HRA: 61-85.6

HS: 34.2-97.3;Mpa: 255-2180N/mm

Measuring accuracy

HV:±3%HV; HRC:±1.5HRC; HB:±3%HB

Indenter

136°vickers diamond indenter

Measuring direction

Support 360°

Data storage

To save 1000-groups of measuring data and 20-groups of calibration data

Hardness scales

HV、HB、HRC、HRA、HRB、MPa

Data display

Loading force, testing-times, testing result, average, maximum, minimum, deviation and conversion scale.

Hardness indication

LCD display

Operating environment

Temperature:-10℃~50℃; humidity: 30%~80%R.H

Operating voltage

DC 4.8V

Dimensions (mm)

160x80x31

Weight (g)

500g(without probe

No.28 Shangdi West Road, Haidian District, Beijing City, China

+86-010-62966798  

+86-010-62985475           +86-010-62980728

export@timegroup.com.cnheyuanyuan@timegroup.com.cn