TIME Group Inc. and Beijing TIME High Technology Ltd. Logo
 

HomeProductsCoating Thickness Gauge > Non-destructive Coating Thickness Gauge TIME®2600
  • Product Name: Non-destructive Coating Thickness Gauge TIME®2600

Guide to TIME2600 Coating Thickness Gauge

TIME 2600 coating thickness gauge

Features

● Two operation principles are adapted: magnetic induction (ferrous) and eddy current (non-ferrous) to take non-destructive measurements

● 6 types of probes are available for different applications

● Features two working modes: DIRECT and BATCH& two measuring ways: CONTINUE and SINGLE

● Statistics include the mean, maximum, minimum, test numbers and standard deviation.

● Memory of 640 data

● Two calibration methods for better correction

● Integrated with printer to print the statists values if needed

● Low battery indication and error alarm

● Backlight for the screen

● Auto or manual shutdown

● Conform to the standards of DIN, ISO, ASTMBS.

 

Standard Delivery

 

Main unit

1

Probe

1

Substrate

1

Calibration foil

1

Charger

1

Printing paper

1

TIME certificate

1

Warranty card

1

Instruction manual

1

 

Technical Specification

Probe types

F

N

Measuring methods

magnetic induction

eddy current

Measuring range

0 ~1250 μm

0 ~1250 μm, 0 to 40μm (for chrome plate on copper)

Minimum resolution

0.1μm

Tolerance

Zero point calibration

±(3%H+1)μm

± (3%H+1.5)μm

H means the thickness of tested piece

Two points calibration

±[(1~3)%H+1]μm

±[(1~3)%H+1.5]μm

H means the thickness of tested piece

Measuring condition

Min. curvature radius (mm)

Convexity 1.5

Convexity 3

Min. testing area diameter (mm)

Ø7

Ø5

Critical thickness of substrate(mm)

0.5

0.3

Standards

DIN,ISO,ASTM,BS

Calibration

Zero and foil calibration

Interface

RS232

Statistic

Number of measurement, mean, standarddeviation, maximum and minimum

Data memory

640 readings

Limits

Adjustable with alarm

Power

NiMH rechargeable battery

Operating environment

Temperature: 0~40

Humidity: 20%~90%

No strong magnetic field

Dimensions (mm)

230×86×47

 

Optional Probes and Application Guide

Probe model

F400

F1

F1/90º

F10

N1

CN02

Operating principle

Magnetic induction

Eddy current

Measuring range (µm)

0-400

0-1250

0-10000

0 to 1250 μm
0 to 40
μm
(for chrome plate
on copper)

10~200

Low range resolution (µm)

0.1

0.1

10

0.1

1

Accuracy

One-point calibration (µm)

±(3%H+1)

±(3%H+10)

±(3%H+1.5)

±(3%H+1)

Two-point calibration (µm)

±[(1~3)H%+0.7]

±[(1~3)H%+1]

±[(1~3)%H+10]

±[(1~3)%H+1.5]

-

Measuring conditions

Min curvature of the min area (mm)

Convex   1

1.5

Flatten

10

3

Flatten

Diameter of the min area (mm)

φ3

φ7

φ7

φ40

φ5

φ7

Critical thickness of substrate (mm)

0.2

0.5

0.5

2

0.3

unlimited

 


No.28 Shangdi West Road, Haidian District, Beijing City, China

+86-010-62966798  

+86-010-62985475           +86-010-62980728

export@timegroup.com.cnheyuanyuan@timegroup.com.cn