Haze Meter TCS-110

零售价

市场价

Adopt dual standards ISO&ASTM, dual caliber (21mm/7mm) is suitable for one-stop measurement solutionsfor haze and transmittace of transparent and translucent materials such as plastics, films, glass, LCD panels and touch screens.

I want to make an inquiry

重量

kg

Quantity
-
+

库存

隐藏域元素占位

  • Product Detail
  • Specifications
  • Videos
    • Commodity name: Haze Meter TCS-110

    Adopt dual standards ISO&ASTM, dual caliber (21mm/7mm) is suitable for one-stop measurement solutionsfor haze and transmittace of transparent and translucent materials such as plastics, films, glass, LCD panels and touch screens.

    1. It conforms to both ASTM and ISO international standards ASTM D 1003,ISO 13468,ISO 14782, JIS K 7361 and JIS K 7136.

    2. Instrument is with a calibration certification from a third party laboratory.

    3. No need to do warm-up, after instrument is calibrated, it can be used. And measurement time is only 1.5 seconds.

    4. Three kinds of illuminants A,C and D65 for haze and total transmittance measurement.

    5. 21mm test aperture.

    6. Open measurement area, no limit on sample size.

    7. It can realize both horizontal and vertical measurement to measure different kinds of materials such as sheets, film, liquid, etc.

    8. It adopts LED light source whose lifetime can reach 10 years.

  • Model

    Professional Edition Haze Meter

    Character

    ASTM D1003/D1044 and ISO13468/ISO14782 standard for haze measurement and light transmittance measurement.

    Open measurement area and samples can be tested vertically and horizontally. Application: glass, plastic, film, display screen, packaging and other industries.

    Illuminants

    D65,A,C

    Standards

    ASTM D1003/D1044, ISO13468/ISO14782, GB/T 2410,JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136

    Test Parameter

    ASTM and ISO (HAZE),Transmittance (T)

    Test Aperture

    21mm

    Instrument Screen

    5 inches color LCD screen

    Haze Repeatability

    Φ21mm aperture, Standard Deviation: within 0.08(when a haze standard with value 40 is measured 30 times at 5-second interval after calibration)

    Transmittance Repeatability

    ≤0.1 unit

    Geometry

    Transmittance 0/D (0 degree illumination, diffused receiving)

    Integrating Sphere Size

    Φ154mm

    Light Source

    400~700nm full spectrum LED light source

    Test Range

    0-100%

    Haze Resolution

    0.01 unit

    Transmittance Resolution

    0.01 unit

    Sample Size

    Open space, no size limit

    Data Storage

    20,000 pcs of samples

    Interface

    USB

    Power Supply

    DC12V (110-240V)

    Working Temperature

    +10 – 40 °C (+50 – 104 °F)

    Storage Temperture

    0 – 50 °C (+32 – 122 °F)

    Size

    L x W x H: 310mmX215mmX540mm